IntelliSense
®
Manual
5
IntelliSense
®
Architecture
IntelliSense
®
is designed to be scalable in its implementation. It is easy to go from a single standalone SIM to multiple
SIMs on a MODBUS RTU network with remote access using an IntelliSense
®
Data Gateway. The development of an
IntelliSense
®
installation requires merging of four traditionally disparate sub-systems, Pneumatic, Data, Controls, and
Power.
Pneumatic Architecture
IntelliSense
®
is intended for use with double acting, single rod end, Bimba Original Line Cylinders. One IntelliSense
®
Sensor Interface Module (SIM) and two sensors are required for each cylinder to be monitored. No other pneumatic
devices should be located between the cylinder port and the sensor tting. For more details on mounting location
and orientation, see the Sensor Installation section later in this manual.
IntelliSense
®
is designed to be easily tted into new and existing applications. Each IntelliSense
®
kit is sized based
on the included pneumatic ttings. IntelliSense
®
kits include two in-line push to connect ttings designed for use with
Nylon, Polyethylene, or 95-D Polyurethane tubing. Six ttings sizes are available: 5/32" or 4mm, 6mm, 1/4", 5/16" or
8mm, 10mm, and 3/8" outer diameter tubing. Custom ttings may also be used. The port on the IntelliSense
®
sen-
sors is a 10-32 thread.
Data Architecture
The Data sub-system is used to provide detailed system information to monitor and diagnose the connected pneu-
matics. In addition, the data network is used to congure the alerts and events that dene the operation of the SIM.
There are two ways to access the data provided by the SIM via a direct connection to a Windows PC or by using an
IntelliSense
®
Data Gateway to connect remotely.
PC
To connect an IntelliSense
®
Sensor Interface Module to a PC, use the IntelliSense
®
Programing Cable (CBL-IS-
RU-1.8). This cable provides a RJ45 to USB Serial connection between the PC and the IntelliSense
®
SIM. This con-
guration is ideal for setting up a standalone system, checking on the status of a cylinder after the SIM has sent an
alert to a PLC, or after a SIM status light change.
IntelliSense
®
Data Gateway
The addition of an IntelliSense
®
Data Gateway greatly enhances the data gathering capabilities of an IntelliSense
®
installation. The IntelliSense
®
Data Gateway is capable of connecting 1 – 12 SIMs to a LAN or the internet. The Intel-
liSense
®
Data Gateway also has the ability to store 100+ Gb of performance data.
Single SIM
Adding a single SIM to the IntelliSense
®
Data Gateway requires an IntelliSense
®
Programing Cable (CBL-IS-RU-1.8).
Multiple SIM
The IntelliSense
®
Data Gateway has three available USB ports that can be used to connect IntelliSense
®
SIMs either
using an IntelliSense
®
Programing Cable or a 4 Port R422 to USB Hub (ISH-D04). The 4 Port R422 to USB Hub (ISH-
D04) can be connected to a SIM’s PC port using a DB9 to RJ45 Cable (CBL-IS-RD-0.5 or CBL-IS-RD-0.5). See the
Cable Pin Out section of the appendix for details on the DB9 to RJ45 cable.
Controls Architecture
The IntelliSense
®
Sensor Interface Module has the ability to be a slave device on a MODBUS RTU network. More
information can be found in the Using IntelliSense
®
with MODBUS RTU Networks section.