IntelliSense
®
Manual
27
button shown in the gure below.
Figure 16: IntelliSense
®
Mode Selection
Identication
When in Cylinder Monitoring mode, three pieces of information can be entered for identifying the SIM. The rst ID is
the SIM name (60 characters max), the second is the cylinder location (40 characters) and the third is the cylinder
part number (32 characters).
Figure 17: Cylinder mode Identication
In Pressure Monitoring mode, the rst ID is the SIM name (60 characters max), the second is the location of sensor
one (40 characters) and the third is the location of sensor two (32 characters).
Figure 18: Pressure / Temperature Monitoring mode Identication
Sensor/Cylinder Setup
Enter the date that the cylinder was put into service. This section has the following commands:
a. Reset cycle count to zero: resets the current cycle count to zero.
b. Set Sensor(s) As Recognized: each sensor has a unique identier to prevent sensors from accidentally
being switched around unknowingly. Whenever a new sensor is connected to a sensor port, the status
screen will show it as being unrecognized. This command will store the IDs of both attached sensors to
the SIM and sets them as recognized.
c. Take baseline: This command button triggers a baseline. A baseline tells the user how the cylinder is
currently performing. These values are for the users reference only and not used by the SIM. On run-
ning the command, a pop-up window appears requesting the number of cycles over which to measure
the baseline (the default is 20 cycles). The SIM will then monitor the cylinder to complete the required
number of cycles and determine values for the stroke time and leakage performance of the cylinder and
Zobrazit stránku 26