Bimba IntelliSens Uživatelský manuál Strana 40

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 68
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 39
IntelliSense
®
Manual
40
Figure 47: Data Export Screen
Pressure and Data Export
Logged data can be exported to the user’s local machine for further analysis. The format is comma separated text le
(CSV) which can be easily opened and edited with spreadsheet or database program.
The following data is available for export. Note that time and pressure measurements 1 and 2 are exported by default
and cannot be selected by the user.
Measured Data
Time Time and date of measurement – not user selectable
Pressure 1 Sensor 1 absolute pressure measurement – not user selectable
Pressure 2 Sensor 2 absolute pressure measurement – not user selectable
Sensor 1 Temperature Sensor 1 temperature
Sensor 2 Temperature Sensor 2 temperature
Line Pressure Absolute line pressure for the cycle
Ambient Pressure Ambient/atmospheric absolute pressure
Extend Time Extend time for the stroke in seconds
Retract Time Retract time for the stroke in seconds
Dwell Time – Extend Dwell time after extending in seconds
Dwell Time – Retract Dwell time after retracting in seconds
Cycle Count Current cycle count
Average Daily Cycles The average daily cycles at the time of measurement
Zobrazit stránku 39
1 2 ... 35 36 37 38 39 40 41 42 43 44 45 ... 67 68

Komentáře k této Příručce

Žádné komentáře