baseline. If numerous snapshots are being taken within short periods of time that show an oscillation of performance,
i.e. a decrease in the performance parameter followed by an increase, the sample size should be increased to reduce
this uctuation. For more details on setting up event detection, refer to the section in this manual: Event Detection
The legend below, the table of data, explains each of the column names with units.
Selecting the Download Events button downloads all of the event snapshot data in a comma-separated value le
(CSV) for further analysis in a spreadsheet or database program.
Figure 53: Event log
Figure 54: Event log legend
Events Reason
When an Event is logged by the SIM unit it records the Reason the event was triggered. These events are coded as
follows.
• Avalueof0canmeanthreethings.
o This is the initial event snapshot.
o Was a user commanded “Baseline” snapshot. It’s recommended to take “Baseline” snapshot using
a cycle count different then the “Sampling Window” so it can be easily identied.
o The event was triggered by the improvements of the tracked parameters.
• Avalueof4meanstheeventwastriggeredbytheextendtimewindowchanginginthepositivedirection
equal or greater than the value of the “Extend/Retract time” change parameter.
• Avalueof8meanstheeventwastriggeredbytheextendtimewindowchanginginthenegativedirection
equal or greater than the value of the “Extend/Retract time” change parameter.